Originaldokument

Produktkunskap

Installation Manual

CDX – Installation Manual

N219

Warning Warning Caution 0(m) 7 5 (ft) 20 10 0 10 20

0 (ft)

6 8 5 7 1.8 2.4 (m) 0 0

10 20 30 40 50(ft)

0 10 20 30 40 50(ft)

0 5 10 15(m)

0 5 10 15(m)

5(ft) 0 5 1 0 1 2 (m) 2

0 10 20 30 40 60 7050 80(ft)

0 5 10 15 20 24(m)

0 10 20 30 40 60 7050 80(ft)

0 5 10 15 20 24(m)

0 (ft)

6 8 1.8 2.4 (m) 0 1m

1 2

MW

(CDX-DAM only)

PIR

MW

(CDX-DAM only)

PIR

Wall tamper knockout

INSTALLATION INSTRUCTIONS

No.59-1900-1 CDX seriesCDX series

TOP VIEW

SIDE VIEW

TOP VIEW

SIDE VIEW

DETECTION AREA3

KNOCKOUTS2

INSTALLATION HINTS1

Corner mount knockout Mounting knockout Corner mount knockout

Wiring knockout

COMPLIANCE How to release the unit base >> Put up the base Remove When using a wall tamper >> Use the knockout for a wall tamper. If the main unit is taken from the wall, the gray section will break away and stay on the wall and the tamper switch will operate. When installing on a plaster board wall or other soft material, cut out the gray area from the back plate. Note >> This symbol indicates prohibition. This symbol indicates recommendation. Grade 3 INDOOR DETECTORGrade 3 INDOOR DETECTOR • Use both knockouts (1) and (2) with included screws. (Self tapping 3 X 16 mm: 3 pcs.) • For corner installation, use both knockouts (3) and (4) with included screws. (Self tapping 3 X 16 mm: 3 pcs.) • CDX series complies with following Directives / Standards. Directive: EMC Directive 2004/108/EC Applied Standards: EN 50130-4: 1995 +A1: 1998 +A2: 2003

EN 55022: 2006

EN50131-1 Grades and Environmental Class: Environmental Class 2 and Security Grade 3. Applide Standards: EN 50131-2-2 (CDX-NAM / CDX-AM)

EN 50131-2-4 (CDX-DAM)

• CDX DAM also complies with following Directives / Standards marked Class II, Directive: R&TTE Directive 1999/5/EC Applied Standards: EN 300 440-1: 2009

EN 300 440-2: 2009

EN 301 489-1: 2008

EN 301 489-3: 2002

EN 50371: 2002

EN 60950-1: 2006 +A11: 2009

The following table indicates the areas of intended use of the equipment and any known restrictions. For countries not included in this list, please consult the responsible Spectrum Management Agency. * Specifications and design are subject to change without prior notice.

SPECIFICATIONS10

FCC ID: DC9 OPMW IC: 4012A-OPMW

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause undesired operation.

COMPLIANCE

OPTIONLED INDICATION9

LightBlink OFF Red LightBlink OFF Red GreenYellow Blinks for approx. 60 sec. Lights for 2 sec. Blinks 3 times and goes off for 3 sec, and repeats. Blinks 4 times and goes off for 3 sec, and repeats. Blinks 5 times and goes off for 3 sec, and repeats.

DETECTOR CONDITION LED INDICATOR

Warm-up Alarm Trouble output Anti-masking detection Local Self test Low voltage detection Remote Self test x3 times x4 times x5 times Model Country of intended use Austria Belgium Denmark Finland France Greece Ireland Italy Luxembourg The Netherlands Spain Sweden United Kingdom Other non-EU: Iceland Norway Switzerland 9.900GHz 10.525GHz 10.525GHz 9.900GHz 10.587GHz 10.525GHz 10.587GHz 10.525GHz 10.525GHz 10.525GHz 10.525GHz 10.525GHz 10.587GHz 10.525GHz 10.525GHz 10,525GHz Restrictions Country of intended use Restrictions

CDX-NAM CDX-AM CDX-DAM

Passive infrared Passive infrared & Microwave EN50131-2-2 (Grade 3) AIR type 24m × 2m (80ft. × 7ft.) narrow [20 zones] 15m × 15m (50ft. × 50ft.) 85° wide [82 zones]

9 - 18VDC

N.C. 28V DC 0.2A max. N.C. 28V DC 0.2A max.

-10°C - +50°C (14°F - 122°F)

No alarm 10V/m 1.8 - 2.4m (6ft. - 8ft.) 180g (6.3oz) 140×70×52.3mm (5.51×2.76×2.06 inches) 95% max. N.C. Opens when cover is removed or the wall tamper switch operates. 28V DC 0.1A max.

EN50131-2-4

(Grade 3) 17mA (normal) / 20mA (max.) at 12V DC 19mA (normal) / 26mA (max.) at 12V DC Detection method Detector standard Masking detection method PIR Coverage [Detection zones] Power supply Alarm output Tamper switch Trouble output Operating temperature Environmental humidity RF interference Mounting height Weight Dimensions

(H×W×D)

Current consumption

OPTEX CO., LTD. (JAPAN)

(ISO9001 Certified) (ISO14001 Certified) 5-8-12 Ogoto Otsu Shiga 520-0101 JAPAN

TEL: +81-77-579-8670 FAX: +81-77-579-8190

URL: http://www.optex.co.jp/

OPTEX INCORPORATED (USA)

TEL: +1-909-993-5770

Tech: (800)966-7839 URL: http://www.optexamerica.com/

OPTEX (EUROPE) LTD. (UK)

TEL: +44-1628-631000

URL: http://www.optex-europe.com/

OPTEX SECURITY SAS (FRANCE)

TEL: +33-437-55-50-50

URL: http://www.optex-security.com/ OPTEX SECURITY Sp. zo. o. (POLAND)

TEL: +48-22-598-05-55

URL: http://www.optex.com.pl/

OPTEX KOREA CO., LTD. (KOREA)

TEL: +82-2-719-5971

URL: http://www.optexkorea.com/

OPTEX (DONGGUAN) CO., LTD.

SHANGHAI OFFICE (CHINA)

TEL:+86-21-34600673

URL:http://www.optexchina.com/ FA-1W: Wall Mount Bracket Adjustable ±45° (Horizontally), 0-20° (Vertically downwards) FA-3: Compact Wall & Ceiling Bracket Adjustable ±45°(Horizontally), 0-10° (Vertically downwards)

NOTE

CDX series is only a part of a complete system, therefore we cannot accept complete responsibility for any damages or other consequences resulting from an intrusion. Anti-masking detection Local Self test Low voltage detection Remote Self test x3 times x4 times x5 times Blinks for approx. 60 sec. Lights for 2 sec. Blinks 3 times and goes off for 3 sec, and repeats. Blinks 4 times and goes off for 3 sec, and repeats. Blinks 5 times and goes off for 3 sec, and repeats. Green lights for 2 sec. Yellow Lights for 2 sec.

DETECTOR CONDITION LED INDICATOR

Warm-up Alarm PIR detection MW detection Trouble output • 15m (50ft.) Wide Angle with Down Zone (CDX-AM/CDX-DAM) • 24m (80ft.) Long Range (CDX-NAM) • Respected Double Conductive Shielding (CDX-AM/CDX-NAM) - Extremely High Light and RFI Immunity • Extreme Tough Microwave Module (CDX-DAM) • PLUG-IN EOL Resistors (PEU) • Advanced IR Beam Anti-Masking Technology Caution >> Do not touch the microwave unit to avoid breakdown caused by static electricity. (4) (3) (1) (2)

CDX-AM CDX-NAM CDX-DAM

CDX-AM CDX-NAM CDX-DAM

CDX-AM CDX-NAM CDX-DAM

CDX-AM CDX-NAM CDX-DAM

CDX-AM PIR with active IR anti-masking (Grade 3) CDX-NAM CDX-AM with long and narrow lens (Grade 3) CDX-DAM PIR & Microwave with active IR anti-masking (Grade 3)

HIGH STD

M

L H

TP TPRSTLED ALCOMTR SP (–)

TAMPERTROUBLE ALARM

TP TPRSTLED ALCOMTR SP (–) (+)

TROUBLE

Grade3

CONTROL PANEL

HOW TO SET

CONNECTION OPTION

Grade2

PLUG-IN EOL ALARM TAMPER

5-1 When setting the resistance value with using

PLUG-IN EOL

5-2 When setting the resistance value without using PLUG-IN EOL

SETTING6

WIRING4

PLUG-IN End Of Line resistors (EOL)5

6-2 DETECTION MODE

SP STD

OFFON

CDX-AM CDX-NAM CDX-DAM

CDX-AM CDX-NAM CDX-DAM

CDX-AM CDX-NAM CDX-DAM

CDX-AM CDX-NAM CDX-DAM

CDX-AM CDX-NAM CDX-DAM

CDX-AM CDX-NAM CDX-DAM

CDX-AM CDX-NAM CDX-DAM

CDX-AM CDX-NAM CDX-DAM

6-1 LED ON/OFF

6-3 PIR SENSITIVITY

7 (RESERVED)

6 ANTI MASKING OUTPUT SELECT

5 ANTI-MASKING SENSITIVITY

4 ANTI-MASKING ON/OFF

3 PIR SENSITIVITY

2 DETECTION MODE

1 LED ON/OFF

REMOTE LED (LED operation remote control) >> Also LED can be enabled or disabled remotely from control panel by LED terminal. Ensure to set LED switch “OFF” for this setting. LED enabled Connect LED terminal to 0 V LED disabled No ground to LED terminal (open circuit)

POSITION

STD

(Factory default)

SP

Suitable for standard applications For use in hostile areas where small animals or other objects exist such as fax machines or curtains.

FUNCTION

POSITION

STD

(Factory default)

HIGH

Suitable for standard applications Suitable for site requires greater sensitivity

FUNCTION

POSITION

OFF

ON

(Factory default) The LED lights when someone is detected. The LED does not light even if someone is detected.

FUNCTION

Wire resistors between the appropriate terminals as follows: Three types of signals – ALARM, TROUBLE and TAMPER – can be recognized through the combination of the resistance value and wires for the TR, COM and TP terminals.

TP

TAMPER OUTPUT

REMOTE SELF TEST

REMOTE LED

ALARM OUTPUT

COMMON

TROUBLE OUTPUT

SPARE

POWER INPUT (9-18VDC)

TP RST LED AL COM TR SP (–) (+) MICROWAVE SENSITIVITY

(6-7) (CDX-DAM only) (+)

PLUG-IN EOL

Note>> Check the direction when inserting PLUG-IN EOL. Caution>> • There are several types of PLUG-IN EOL and the insertion direction differs depending on its type. When connecting to a control panel that supports the EOL technique (Factory default)

ON OFF

OFFON

HIGH STD

M

L H

MW SENSITIVITY

L M H

9m (30ft.) 12m (40ft.) 15m (50ft.)

6-5 ANTI-MASKING SENSITIVITY

6-4 ANTI-MASKING ON/OFF

6-6 ANTI-MASKING OUTPUT SELECT

If the microwave sensitivity is set too high, it may detect movements outside of the detection area, resulting in false alarms. By creating a microwave detection area to conform to the PIR detection area, it achieves higher detection performance and preventing false alarms.

6-7 MICROWAVE SENSITIVITY

7-1 LOCAL SELF TEST

7-2 REMOTE SELF TEST

SELF TEST7

TROUBLE OUTPUT SUMMARY8

CDX-DAM

When an object is placed close to the lens surface, for a period of more than 20 seconds then theɹ Anti-Masking circuit will activate and generate a trouble signal. Note>> “A” means activate, “N/A” means not available. Caution>> The above distance indications are guide only. Do not set the MW sensitivity too low. This could cause a MW failure. It is important to adjust the sensitivity so that the MW and PIR detection areas are overlapping. This function checks the operation of detection ability of PIR and Microwave. This ensures that the unit is always working correctly. Local self test is controlled by the detector and runs periodically to test the functionality of the circuitry. If the local self test fails, the TROUBLE relay is activated and LEDs blink (see 9 ). This test may be initiated by the control panel by applying 0V to the RST terminal. If the remote self test passes, the ALARM relay is activated for 5 seconds. If the test fails, the TROUBLE output is activated and the LEDs will blink (see 9 ).

POSITION

STD

(Factory default)

HIGH

Suitable for standard applications Suitable for site requires greater sensitivity

FUNCTION

POSITION

ON

(Factory default) Enabled OFF Disabled

FUNCTION

ON

N/A A

A A

OFF

(Factory defoult)

POSITION OUTPUT TERMINAL

ALARM TROUBLE

7-3 WALK TEST

1m Keep at least 1 meter away from the detector and clear of any objects. Note>> When selecting ON, functions of 6-5 and 6-6 are activated. Anti-masking detection Local Self test Low voltage detection Remote Self test When an object is placed close to the lens surface for a period of more than 20 seconds, then the PIR Anti-Masking circuit will activate and generate a trouble signal. Local self test is controlled by the detector and runs periodically to test the functionality of the circuitry. If the local self test fails, the TROUBLE relay is activated and LEDs blink (see 9 ). This test may be initiated by the control panel by applying 0V to the RST terminal. If the remote self test passes, the ALARM relay is activated for 5 seconds. If the test fails, the TROUBLE output is activated and the LEDs will blink (see 9 ). When the power supply voltage drops, the low voltage detection circuit activates and outputs

TROUBLE.

The terminal that is output when anti-masking is detected can be switched with this switch. Detector Wall Good No good (Penetration)

PEU