OPISINSTALLATIONMANUAL

Produktkod: OPISINSTALLATIONMANUAL

Brand: Alarmtech

Språk: EN

Produktkunskap för OPISINSTALLATIONMANUAL

Originaldokument

Produktkunskap

Installation Manual

OPISINSTALLATIONMANUAL – Installation Manual

code R30015.110en www.kseniasecurity.com ed. 04/2023 opis Supervised Power Supply Station

Installation guide

INTRODUCTION

opis is a device that allows to extend the BUS on two additional branches. The power supply to the branches it is provided by the same opis, protected by an 1.5 A auto restoring thermal fuse. The device is fully supervised by the panel, with BUS status, power supply voltage and battery charge information. The opis power station is supplied already wired in the large metal cabinet (325 x 400 x 90 mm) with key lock, equipped with a 2A / 220V fuse and a 3A switching power supply.

PCBA TECHNICAL DATA

• Battery management: 18 Ah • Power supply: 14.2 Vdc • Consumption: 50 mA stand-by; 950 mA max • Operating temperature range: -10 +40 °C; 95% Humidity • Dimensions: 115x60x20 mm (PCBA) •W e i g h t : 5 0 g • Maximum current available for external de vices: 1450mA grade 2 - 550mA grade 3 code R30015.110en www.kseniasecurity.com ed. 04/2023

DESCRIPTION OF PCBA CONNECTIONS

TEMINALS DESCRIPTION

12V + / - : Power supply input 14.2Vdc : Protection ground +P : Output 12V power supply (1.5 A max) BUS IN A B : Connection terminals of lares 4.0 control panel + : Short circuit [+] terminal of BUS IN with [+P] terminal of opis - : Do not connect terminal [-] of opis BUS 1 + A B - : Connection terminals to the output BUS 1 BUS 2 + A B - : Connection terminals to the output BUS 2

14.2V

LEGEND

1. Reserved Terminals

2. Microswitch tamper

3. Signalation LEDs (M-B-S)

see description in the following table

4. Backup battery connector

5. Connection terminals

6. Micro-controller

7. Backup battery

8. Power supply

9. Protection ground

10. Protection fuse

code R30015.110en www.kseniasecurity.com ed. 04/2023

POWER SUPPLY STATION TECHNICAL DATA

• Power supply voltage: 230 V~ -15/+10% 50 Hz 0.8 A • Power Supply Battery Charger* (Type A norm EN50131-6): 14.2V ± 1% 50W • Current consumption (medium): 50mA • Current consumption (max): 100mA • Maximum current available for external devi ces: 1450 mA grade 2 - 550 mA grade 3 • Max. output voltage ripple: 13.8 V- da 10 a 15 V- 120 mV • Max. current for battery charging: 750 mA • Maximum battery recharge time to 80%: 12 V – 18 Ah 24 h • Deep discharge voltage protection: 10 V • Low battery threshold (restore): 11 V- (12.5 V-) • Low voltage threshold: 11 V- • Over voltage protection voltage: 17.5 V • Backup battery: 18Ah • Overall dimensions (WxHxD): 325x400x90 mm • Weight (with battery): 4.2 Kg (10 Kg) • Temperature operating range: -10 / +40 °C - Humidity (not condensed): 95 % * Note: The power supply is calibrated at 15V, compatible with control panels of lares 4.0 family. When using with lares control panels or with opis, act on the trimmer of charger to adjust the voltage at 14.2V. LEDs SIGNALATION (M - B - S) M Power Supply status Steady: Correctly working Off: Power supply fault or missing AC network B Battery Voltage status Steady: Correctly working Off: Fault or low battery level S System Status Steady: Correctly working Flashing: Tamper and/or BUS IN connection fault detail of PCBA: LEDs code R30015.110en www.kseniasecurity.com ed. 04/2023

DESCRIPTION OF POWER SUPPLY STATION CONNECTIONS

NOTE: insert a ferrite ring on the power cable during cabling.

LEGEND

1. Metal bottom

2. Holes for passing cables

3. Bottom securing holes

4. opis PC board brackets

5. Trimmer to adjust the voltage

at 14.2

6. Holes for cables fixing

7. Backup battery

(Flammability class UL94-HB)

8. Battery terminals

9. Protection ground

10. Protection fuse 2A

11. Micro-switch cable +

Anti-tamper micro-switch code R30015.110en www.kseniasecurity.com ed. 04/2023

INSTALLATION

Installing opis PCBA inside the metallic box (accessory code KSI7403130.010 or KSI7404130.010) with power station (adjust it at 14.2V):

1. Fix the metal cabinet to the wall using Ø 0.32 inch screws (options)

2. Place the opis PCBA in the metallic box with power supply charger

3. Perform the necessary links between the opis PCBA and the power supply, as described in the paragraph

“DESCRIPTION OF POWER SUPPLY STATION CONNECTIONS” page 4

4. Ensure the cables to the fixing holes

5. Arrange outside the Panel an isolating device (i.e. Circuit Breaker Device 16A Curve C).

6. The power supply has an internal protection fuse (50W - F3.15AL).

7. Wire the earth connection directly on the power supply unit.

8. The power supply conductors must be 0.6 inch.² minimum section.

9. In case of failure or maintenance, the opening of the metallic box must be carried out by authorized

personal.

QUANTITY DATA

CERTIFICATIONS

Europe - RoHS, CE

EN 50131-6:2017 - EN 50131-1:2006 + A1:2009 + A2:2017 + A3:2020

Grade 2 (1450 mA) - Grade 3 (550 mA) Class II

T031:2014

Technical data, appearance, functionality and other product characteristics may change without notice. lares 4.0 models wls 96 16 40 40 wls 140 wls 644 wls Maximum number of expansion modules isolator opis

2 4 12 12 20 32